Gå til hovedindhold

Billigste pris lige nu: 282 kr hos Bels (DK).

Se pris på Lapp Ölflex tray ii cy 4g2,5 r76

1 tilbud fra dansk forhandler. Pris lige nu: 282.23 kr.
Bels (DK)
Bels (DK)
På lagerNy vare
282,23 kr
Lapp Ölflex tray ii cy 4g2,5 r76 billede

Lapp Ölflex tray ii cy 4g2,5 r76

ÖLFLEX® TRAY II CYUL TC-ER 600V, AWM 1000V WET 75°C SUN/ OIL RES I+II DIR BUR CSA AWM I/II A/B FT4Screened PVC power control cable 0.6/1 kV, Tray Exposed RunBroad application range (NFPA 70/NEC), NFPA 79 complianceApplication rangeUnprotected 600V operation on cable tray in the USA, incl. 6 ft. Exposed Run laying sectionsCompliant with Tool machines: (UL) MTWUSA Wind Turbine Tray Cable (WTTC)Product featuresFlame-retardant according to CSA FT4UL Vertical-Tray Flame TestOil-resistant according to UL OIL RES I & IIWater-resistant, UL 75°C WET ratingUV resistant (SUN RES), Ozone resistantSuitable for torsional applications which are typical for the loop in wind turbine generators (WTG)Norm references / ApprovalsUSA: (UL) TC-ER [E171371], (UL) MTW [E155920], (UL) WTTC [E323700], Submersible Pump (14 - 2 AWG), (UL) PLTC-ER(18 - 12 AWG) [E216027], (UL) ITC-ER (18 - 12 AWG) [E196134], (UL) DP-1 [E233406], UL AWM (18 - 2 AWG) [E100338]UL OIL RES I/ II, 75°C WET, 90°C DRY, SUN RES, DIR BUR, NEC/NFPA 70, NFPA 79CAN: c(UL) CIC/ TC 600V FT4 (< 250 kcmil) [E171371], CSA AWM I/II A/B FT1ProductFine-wire strand made of bare copper wiresInsulation: PVC+nylon sheath (PA skin)Aluminum-coated foilTinned-copper braidingOuter jacket: Specially formulated thermoplastic polymerColor of the outer jacket: BlackTechnical DataCore identification code: Black with white numbersConductor stranding: Fine copper wire strandsTorsion movement in WTG: TW-0 & TW-2, refer to Appendix T0Minimum bending radius: Static/Occ. moved: 5/20 x OD*Nominal voltage: UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000 VUL/CSA: 1000 V (AWM)Protective conductor: G = with GN-YE protective conductor, X = without protective conductorTemperature range: -40°C (static)/ -25°C (occ. moved) to +90°C (AWM: +105°C) Lapp Ölflex tray ii cy 4g2,5 r76

EAN: 4044774613239Varenr.: 4044774613239

Priser opdateret

Prisoversigt

Tilbuddet på Lapp Ölflex tray ii cy 4g2,5 r76 lige nu. Tabellen viser pris, rabat og forventet leveringstid.

Prisoversigt — tilbuddet på Lapp Ölflex tray ii cy 4g2,5 r76. Tabellen viser pris, rabat og forventet leveringstid.
#ForhandlerPrisLagerLeveringHandling
1Bels (DK)282,23 krPå lagerKøb

Om produktet

Pris og forhandlere lige nu

Produktet sælges lige nu af 1 dansk forhandler, Bels (DK), til 282 kr. Produktet hører til kategorien Eludstyr.

Beskrivelse

Fra forhandleren Bels (DK):
ÖLFLEX® TRAY II CYUL TC-ER 600V, AWM 1000V WET 75°C SUN/ OIL RES I+II DIR BUR CSA AWM I/II A/B FT4Screened PVC power control cable 0.6/1 kV, Tray Exposed RunBroad application range (NFPA 70/NEC), NFPA 79 complianceApplication rangeUnprotected 600V operation on cable tray in the USA, incl. 6 ft. Exposed Run laying sectionsCompliant with Tool machines: (UL) MTWUSA Wind Turbine Tray Cable (WTTC)Product featuresFlame-retardant according to CSA FT4UL Vertical-Tray Flame TestOil-resistant according to UL OIL RES I & IIWater-resistant, UL 75°C WET ratingUV resistant (SUN RES), Ozone resistantSuitable for torsional applications which are typical for the loop in wind turbine generators (WTG)Norm references / ApprovalsUSA: (UL) TC-ER [E171371], (UL) MTW [E155920], (UL) WTTC [E323700], Submersible Pump (14 - 2 AWG), (UL) PLTC-ER(18 - 12 AWG) [E216027], (UL) ITC-ER (18 - 12 AWG) [E196134], (UL) DP-1 [E233406], UL AWM (18 - 2 AWG) [E100338]UL OIL RES I/ II, 75°C WET, 90°C DRY, SUN RES, DIR BUR, NEC/NFPA 70, NFPA 79CAN: c(UL) CIC/ TC 600V FT4 (< 250 kcmil) [E171371], CSA AWM I/II A/B FT1ProductFine-wire strand made of bare copper wiresInsulation: PVC+nylon sheath (PA skin)Aluminum-coated foilTinned-copper braidingOuter jacket: Specially formulated thermoplastic polymerColor of the outer jacket: BlackTechnical DataCore identification code: Black with white numbersConductor stranding: Fine copper wire strandsTorsion movement in WTG: TW-0 & TW-2, refer to Appendix T0Minimum bending radius: Static/Occ. moved: 5/20 x OD*Nominal voltage: UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000 VUL/CSA: 1000 V (AWM)Protective conductor: G = with GN-YE protective conductor, X = without protective conductorTemperature range: -40°C (static)/ -25°C (occ. moved) to +90°C (AWM: +105°C) Lapp Ölflex tray ii cy 4g2,5 r76

Specifikationer

Producent
Lapp

Prisudvikling og prishistorik

PriceTracker har fulgt prisen på Lapp Ölflex tray ii cy 4g2,5 r76 i 3 dage. Den nuværende pris er 282,23 kr.

Prisændringer de seneste 6 måneder

Tabellen viser 1 prisændring for Lapp Ölflex tray ii cy 4g2,5 r76. Kun ændringer i laveste pris vises.

Prishistorik — 1 prisændringer for Lapp Ölflex tray ii cy 4g2,5 r76 de seneste 6 måneder.
DatoLaveste prisÆndring
30. aug.282,23 kr

Spar mere

Vi kan ikke altid garantere de laveste priser, da ikke alle forhandlere samarbejder med os. Se vores guides: pristjek på tværs af butikker, rabatkoder og cashback, prismatch og prisgaranti og automatisk prisovervågning med OpenClaw.

Priserne på denne side er sidst kontrolleret